4 changes: 2 additions & 2 deletions go/test/site/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -113,8 +113,8 @@ the fuse and 1.2 × the fuse as Core does: it counts only once its 60 s heat
| `s14-25` One-phase car | an 11 kW charger with a one-phase car, a plan it cannot meet, 20 min | 3.4–3.8 kW over the last 10 min; never called not following | |
| `r1-25` Meter silent, then offline | 25 A, 15 A per phase, battery at 50 %, Charge now 16 A; the site meter silent (Modbus timeouts) for 120 s, then gone for 90 s. **Skipped**: the pinned simulator cannot silence the site meter | the battery relieved the fuse (setup); while silent no offer rises and the battery order only moves toward 0 (**known**: A1); a 0 W order and the battery back on its own within 64 s; the meter never shows live; Charge now back within 95 s of each return and held until the next event; fuse holds | |
| `r2-25`, `r2-60-25` Battery drops out | 25 A, 20 A per phase, the battery held at a 3 kW discharge, a car taking 10 A on Charge now, the charger at once or 60 s late; the inverter gone for 180 s. The site stays under 1.2 × the fuse, where Core cuts the car on its 60 s heat budget, not at once | the battery discharged (setup); fuse holds; over 1.2 × the fuse at most the charger's delay + 7 s; the 60 s heat under 1.13 × the fuse; no offer rises while it is gone; Home use shown as estimated throughout. The time over the fuse and when Core sends the cut are recorded | |
| `r3-25` Planner floor | 25 A, 15 A per phase, battery at 12 %, planner `soc_min` 10 %, inverter floor 5 %, charger 60 s late, Charge now 16 A for 600 s | the battery reaches the floor (setup); no discharge ordered below it (**known**: A4); the battery order swings at most 100 W over the last 5 min (**known**: A3, A4); over the fuse at most the delay + 7 s; fuse holds | |
| `r4-25` Hard kill | 25 A, 12 A per phase, Charge now 16 A; once the day's Home use is known and 10 min more, the battery held at a 3 kW discharge; 5 min later SIGKILL for 20 s, and 2 min after that for 120 s while the house steps to 16 A | Charge now back at its minimum within 60 s of each restart and held until the next kill or the end; the day's Home use kept within 1 % across the first kill; session energy counts again (**known**: E1); no state.db recovery in the log; fuse holds | |
| `r3-25` Planner floor | 25 A, 15 A per phase, battery at 12 %, planner `soc_min` 10 %, inverter floor 5 %, charger 60 s late, Charge now 16 A for 600 s | the battery reaches the floor (setup); no discharge ordered below it; the measured SoC stays at or above it; the battery order swings at most 100 W over the last 5 min; over the fuse at most the delay + 7 s; fuse holds | |
| `r4-25` Hard kill | 25 A, 12 A per phase, Charge now 16 A; once the day's Home use is known and 25 min more, the battery held at a 3 kW discharge; 5 min later SIGKILL for 20 s, and 2 min after that for 120 s while the house steps to 16 A | Charge now back at its minimum within 60 s of each restart and held until the next kill or the end; the day's Home use kept within 1 % across the first kill; session energy counts again; no state.db recovery in the log; fuse holds | |
| `r5a-25` Start beside a charging car | 25 A, 14 A per phase, battery at its 5 % floor, a car charging on its own at 16 A: 30 A per phase for 60 s before Core starts | the car charged and the site was over the fuse (setup); under the fuse within 30 s of Core answering, and over it at most 3 s after; Home use shown within 30 s; fuse holds | |
| `r5b-25` Start on a stale plan | a goal 40 → 60 % 8 h out, Core stopped for 20 min | no positive order in the first 30 s before a fresh plan; Home use shown within 30 s; fuse holds. It does not reach D6 on master: the saved plan is younger than 30 min and a fresh one lands within seconds | |
| `r5c-25` Start into a new session | Charge now, Core stopped for 10 min while the car leaves and another plugs in | Core sees the car within 60 s; Home use shown within 30 s; fuse holds. Whether Charge now carries over is recorded, not judged: ev-088 waits for the owner | |
Expand Down
19 changes: 9 additions & 10 deletions go/test/site/scenarios_p0_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -24,14 +24,9 @@ func init() {
scenario{name: "r2-60-25", dir: "r2-battery-offline-slow60-25A", minutes: 10, run: func(c *runCtx) (map[string]any, error) { return r2(c, 25, 60) },
judge: judgeR2},
scenario{name: "r3-25", dir: "r3-planner-floor-25A", minutes: 13, run: func(c *runCtx) (map[string]any, error) { return r3(c, 25) },
judge: judgeR3,
known: map[string]string{
"no discharge ordered below the planner floor": "A4: fuse relief discharges to 5 %, below planner.soc_min (dispatch.go:4113-4124, 4495-4499)",
"the battery order swings at most 100 W over the last 5 min": "A3, A4: at the inverter's empty 5 % Core keeps ordering 3.9-5 kW of discharge (the slew step reopens it, dispatch.go:2148-2219)",
}},
scenario{name: "r4-25", dir: "r4-sigkill-25A", minutes: 40, run: func(c *runCtx) (map[string]any, error) { return r4(c, 25) },
judge: judgeR4,
known: map[string]string{"session energy counts again after each restart": "E1: a 1.6 transaction is not taken up after a restart, so session_wh stays 0 (handlers.go:615-617, #1787)"}},
judge: judgeR3},
scenario{name: "r4-25", dir: "r4-sigkill-25A", minutes: 41, run: func(c *runCtx) (map[string]any, error) { return r4(c, 25) },
judge: judgeR4},
scenario{name: "r5a-25", dir: "r5a-start-car-charging-25A", minutes: 5, run: func(c *runCtx) (map[string]any, error) { return r5a(c, 25) },
judge: judgeR5a},
scenario{name: "r5b-25", dir: "r5b-start-stale-plan-25A", minutes: 27, run: func(c *runCtx) (map[string]any, error) { return r5b(c, 25) },
Expand Down Expand Up @@ -158,7 +153,11 @@ func r3(c *runCtx, fuse float64) (map[string]any, error) {
// 20 s; two minutes later the second lasts 120 s, and the house steps to
// 16 A per phase while Core is gone. Like s7, the run first waits until the
// day's Home use is known, and long enough after it that one restart stays
// under the 10 % unknown-time rule. Core holds a battery for at most
// under the 10 % unknown-time rule. The rule counts whole ledger minutes,
// so a restart whose unknown car reading crosses a minute boundary marks
// two. With the 42 s Core was down or starting, that came to 128 s of a
// 1 054 s day when the hold came 10 min after, and failed 1 run in 5.
// 25 min leaves room for it. Core holds a battery for at most
// 1800 s, so the hold starts 300 s before the first kill and outlasts both.
func r4(c *runCtx, fuse float64) (map[string]any, error) {
var serial string
Expand All @@ -177,7 +176,7 @@ func r4(c *runCtx, fuse float64) (map[string]any, error) {
}) {
st.mark("today_known")
}
sleepS(600)
sleepS(1500)
st.mark("battery_hold")
if err := st.post("/api/battery/manual_hold", map[string]any{"direction": "discharge", "power_w": 3000, "hold_s": 1800}, nil); err != nil {
return err
Expand Down
10 changes: 10 additions & 0 deletions go/test/site/scenarios_p0_unit_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -181,6 +181,16 @@ func TestJudgeR3(t *testing.T) {
if v["the battery order swings at most 100 W over the last 5 min"] {
t.Fatal("an order hunting between 0 and -3 kW passes")
}
// No order at all, as when Core hands the battery back to the inverter,
// while it runs on from 12 % to the inverter's 5 %.
v = run(func(i int, r *sample) { r.Bat.SoCPct = 12 - 7*float64(min(i, 200))/200 })
if !v["no discharge ordered below the planner floor"] || v["the battery stays at or above the planner floor"] {
t.Fatalf("a battery left to run to 5 %%: %v", v)
}
v = run(func(i int, r *sample) { r.Bat.SoCPct = max(10, soc(i)) })
if !v["the battery stays at or above the planner floor"] || !v["the battery reached the planner floor"] {
t.Fatalf("a battery held at the floor: %v", v)
}
}

func TestJudgeR4SessionEnergy(t *testing.T) {
Expand Down
5 changes: 4 additions & 1 deletion go/test/site/verdicts_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -648,7 +648,9 @@ func judgeR2(d *runData) (metrics, []criterion) {
}

// judgeR3: Core orders no discharge below the planner's floor, its battery
// order settles, and the car answers when the battery stops.
// order settles, and the car answers when the battery stops. The measured
// SoC must hold the floor too: an order of 0 W also reads from a battery
// handed back to the inverter, which would run on to its own 5 %.
func judgeR3(d *runData) (metrics, []criterion) {
fuse, delay, floor := d.metaF("fuse"), d.metaF("charger_delay_s"), d.metaF("planner_floor_pct")
t0, tCN, t1 := d.marks["plug"], d.marks["charge_now"], d.marks["end"]
Expand Down Expand Up @@ -681,6 +683,7 @@ func judgeR3(d *runData) (metrics, []criterion) {
return m, []criterion{
crit("the battery reached the planner floor", len(run) > 0 && minSoC <= floor+0.5), // the setup
crit("no discharge ordered below the planner floor", below <= 10),
crit("the battery stays at or above the planner floor", len(run) > 0 && minSoC >= floor-0.5),
crit("the battery order swings at most 100 W over the last 5 min", len(last) > 0 && swing <= 100),
crit("over the fuse no longer than the charger's delay + 7 s", over <= allowed),
crit("fuse holds", !anyBlown(run)),
Expand Down