Skip to content

[Bug]: Switching device surface can leave a completed turn stuck in "receiving parameters" #3056

Closed

Description

@QZQ-go

Summary

Switching the active device surface while a turn is running can leave the original desktop UI with contradictory state after the host finishes:

  • the session/sidebar indicates that the turn completed;
  • the persisted turn and backend state are terminal (completed / Idle);
  • an earlier Edit tool card remains stuck at receiving parameters;
  • there is no effective Stop action because the backend has already removed the cancellation token.

This appears to be a device-surface event projection/reconciliation issue rather than a runtime deadlock. The settled persisted turn does not fully replace the stale in-memory tool-card projection after returning to the local surface.

Expected: After switching back, or after receiving a settled-turn snapshot, the UI should reconcile every tool item to the host's authoritative persisted state. A completed turn should not retain a streaming/preparing card.

Actual: The sidebar and session metadata show completion while one tool card continues to look active indefinitely. Restarting the desktop app restores a consistent view.

Area

Desktop app / Web UI (peer device surface switching and settled-turn reconciliation)

Reproduction or evidence

A likely reproduction sequence is:

  1. Start a long-running local turn containing several tool calls, including an Edit tool.
  2. While an Edit card is still receiving/streaming its arguments, manually switch control to a peer device surface.
  3. Allow the original host to finish the turn.
  4. Switch control back to the local device and reopen the session.
  5. Observe that the session is marked complete but the earlier Edit card still says receiving parameters, with no meaningful way to stop it.

Evidence from one occurrence (timestamps are local):

  • 09:32:40: the local window became visible and the same turn was attached/projected.
  • 09:32:45: the Agentic event listener was stopped and then registered again.
  • 09:32:46: Device surface switched from local (null) to a peer device (reason: manual).
  • 09:34:18: the host received the final response, completed the turn loop with reason=complete, emitted DialogTurnCompleted, cleaned the cancellation token, and transitioned the backend session to Idle.
  • 10:43:53: the surface switched back from the peer device to local.
  • Subsequent snapshot reconciliation reported backend state Idle and the correct latest turn ID, but the old Edit card remained visually stuck in receiving parameters.

Persisted data for the affected turn confirms:

  • turn status: completed;
  • finish reason: complete;
  • hasFinalResponse: true;
  • all 19 model rounds are completed;
  • all 21 tool calls are completed;
  • the exact Edit tool shown as streaming in the UI has a persisted successful result.

A process sample taken while the UI was stuck showed the normal AppKit/CoreFoundation event loop and no mutex/thread deadlock. There were no child tool processes still running.

There were also repeated get_operation_diff: Session not found / get_operation_summary: Operation not found warnings for file-operation cards that modified a file outside the active workspace. These may make the stale card more visible, but the host turn itself completed successfully and they may be a separate degradation issue.

Environment, if relevant

  • OpenBitFun: 1.0.0
  • Build commit: a0d6a6fe53e0d86fa81d61390cf6f661e8a55307
  • Build date: 2026-09-15T09:04:07.335Z
  • OS: macOS 27.0 (26A428)
  • App mode: native desktop app, local workspace with peer device surface switching
  • Model shown in the affected session: GLM 5.3 (the issue appears independent of provider/model)

Activity

  1. bobleer commented on Nov 2, 2026

    @bobleer
    Collaborator

    Thanks for the detailed timeline and the persisted-turn evidence. This is fixed on main by #3690.

    Root cause: while the peer surface was shown, the turn's later chunks and DialogTurnCompleted were dropped. On return, the refresh fell back to restore_session_view with the host Idle, but the complete persisted turn was refused because the local stream still thought it owned a running turn, so the Edit card stayed at its last streamed state ("receiving parameters"). #3690 adopts the settled host record when the host reports it is not executing that turn, which replaces the stale card. We also checked it with a test reproducing exactly this case: a live Edit card still receiving parameters, refreshed against a completed persisted record with the host Idle. The test passes on #3690 and fails without it.

    The get_operation_diff: Session not found warnings for files outside the workspace look like a separate issue; please open one if they still show up after upgrading.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions