The F25 Ultra reports DyadCleanMode codes 5 (hot water) and 6 (steam), which were logged as missing and decoded as "auto". Add both modes and an explicit `unknown` member so future unknown codes no longer masquerade as "auto".
allenporter
approved these changes
Nov 8, 2026
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
The Roborock F25 Ultra reports
DyadCleanMode(DP205) codes that the library does not know, which produces warnings in Home Assistant and decodes the heated modes asauto:Changes
hot_water = 5andsteam = 6toDyadCleanMode.unknown = -1member, per the enum fallback rules inAGENTS.md, so future unknown codes fall back tounknowninstead ofauto.DyadCleanModeis removed from theKNOWN_ENUMS_MISSING_UNKNOWNbaseline accordingly.3(dehydration). The name is kept so existing Dyad models are unaffected.Verification on a real device
Mapping confirmed on an F25 Ultra by switching modes in order Steam → Hot water → Sponge → Auto with debug logging enabled:
The branch was also installed in Home Assistant 2026.11.0 (as a custom component override); the warnings no longer appear.
DPs
238,244and245are not part ofRoborockDyadDataProtocolyet; they are left for a separate change.Tests
pytest tests/data/test_code_mappings.py tests/conformance tests/devices/traits/a01 tests/devices/test_a01_traits.py: 405 passed, 52 xfailedruff check/ruff format --checkon changed files: clean