Skip to content

feat(connectors): add Kelmarsh, Penmanshiel and Hill of Towie wind farm connectors - #838

Open
Gsoulja wants to merge 1 commit into
OpenTSLM:mainfrom
Gsoulja:feature/kelmarsh-connector
Open

Gsoulja wants to merge 1 commit into
OpenTSLM:mainfrom
Gsoulja:feature/kelmarsh-connector

Conversation

@Gsoulja

@Gsoulja Gsoulja commented Nov 21, 2026

Copy link
Copy Markdown

Summary

Adds three open wind-farm SCADA datasets as connectors, the first wind data in the catalog:

Dataset Turbines Years Labels
cubico/kelmarsh 6 Senvion MM92 (2,050 kW) 2019-2022 Operator status log: each stop annotated with its IEC category and message; curtailments too
cubico/penmanshiel 14 Senvion MM82 (2,050 kW) 2019-2022 Same as Kelmarsh (shared Greenbyte export code)
res/hill_of_towie 21 Siemens SWT-2.3-VS-82 (2,300 kW) Jan 2016 - Aug 2024 Shutdown durations published by RES

One Record is one turbine for one UTC day: 144 ten-minute steps of active power, wind speed, blade
pitch angle, rotor speed, nacelle direction and ambient temperature. A step the source leaves empty
stays missing.

Tasks:

  • Kelmarsh and Penmanshiel: stopped on the day, stopped minutes, stop intervals, main stop reason.
  • Hill of Towie: shut down on the day, minutes, ten-minute periods, and at least 60 minutes of
    downtime at wind of 4 m/s or more.

All sources are CC-BY-4.0 Zenodo records, pinned by URL and SHA-256. Each connector has
fixture-based tests that call convert() on a small synthetic export, with no network access.

The branch is rebased on main and follows #797 (label-set names as annotations) and #822
(download returns one value, positional raw).

We built these for the TimeNet hackathon: a time-series language model that answers questions
about wind-turbine downtime from these days, trained on the two Senvion farms and tested on Hill of
Towie.

Checks

  • make check and make check-ci (hooks over all files, plus ty on Python 3.11): pass
  • make test: 2,986 passed, 1 skipped, 2 xfailed
  • make test-connectors: all connectors pass, including the three new ones (18, 4 and 13 tests)
  • make license-check: pass (no dependency changes)
  • Not run after the rebase: a full timenet-build build round trip, because the sources are large
    downloads. A full local build of all three was done with the connector code before the rebase.

🤖 Generated with Claude Code

…rm connectors

Add three open wind-farm SCADA datasets (CC-BY-4.0), the first wind data in the catalog.
One Record is one turbine for one UTC day: 144 ten-minute steps of active power, wind
speed, blade pitch angle, rotor speed, nacelle direction and ambient temperature.

- cubico/kelmarsh (6 Senvion MM92) and cubico/penmanshiel (14 Senvion MM82), 2019-2022:
  labels from the operator's status log; each stop is annotated with its IEC category and
  message, curtailments too. Tasks: stopped on the day, stopped minutes, stop intervals,
  main stop reason.
- res/hill_of_towie (21 Siemens SWT-2.3-VS-82), January 2016 to August 2024: labels from
  the shutdown durations RES published. Tasks: shut down on the day, minutes, ten-minute
  periods, and at least 60 minutes of downtime at wind of 4 m/s or more.

Each connector has fixture-based tests that call convert() without network access.
Checked with make check, make check-ci, make test, make test-connectors and
make license-check.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

This branch has not been deployed

No deployments
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.