Skip to content

feat(connectors): add fraunhofer-iee/care-to-compare - #792

Open
ShaoSK wants to merge 3 commits into
OpenTSLM:mainfrom
ShaoSK:feature/care-to-compare
Open

ShaoSK wants to merge 3 commits into
OpenTSLM:mainfrom
ShaoSK:feature/care-to-compare

Conversation

@ShaoSK

@ShaoSK ShaoSK commented Nov 17, 2026

Copy link
Copy Markdown

Adds a connector for CARE to Compare (Fraunhofer IEE), a real-world benchmark for early fault detection in wind turbine SCADA data. It is the first energy/industrial dataset in the catalog.

Source

What the dataset holds

  • 95 Records, one per event file: 45 anomaly events (leading up to a documented turbine fault) and 50 normal events, across 36 turbines in 3 wind farms (A: 5 onshore, B: 9 and C: 22 offshore).
  • Per Record: one Signal per sensor statistic at 10-minute resolution (A 81, B 252, C 952) on a RegularAxis, plus the turbine's operating status (status_type_id). Skipped grid steps and empty cells are nulls. Units map to pint where unambiguous; otherwise the release string is kept as a source_unit annotation.
  • Annotations: wind farm, asset, event label, root-cause note, training_period, prediction_period, and the event_window interval.
  • Tasks:
    • ClassificationTask (event_label: anomaly / normal) scoped to the prediction period, for every Record.
    • TemporalLocalizationTask targeting the event_window annotation, for every anomaly Record.
    • ClassificationTask (fault_component) for the 18 anomaly events of farms A and B, derived from the release's root-cause notes (documented on the card as TimeNet-derived).
  • No split across events: the release defines a training and a prediction period inside each Record.

Implementation notes

  • source.py parses and validates the release: header, row IDs, the 10-minute grid, a single asset per file, training rows before prediction rows, and event windows on the grid. It has no TimeNet types, so it is tested on its own.
  • Wind farm A names its eight energy counters (sensor_44 to sensor_51) without a statistic suffix. They read as their sensor's single statistic. All three farms' headers were checked against their feature descriptions.
  • connector.py caches each event's values as a feature-major .npy next to the extracted CSV and builds Signals with Signal.from_loader, so a build holds one event in memory at a time (wind farm C alone is about 17.8 GB of CSV).
  • Tests use a synthetic wind farm in the release's shape (gaps, empty cells, a bare counter column, both asset column names, quoted descriptions) and include a storage round trip.

Verification

  • pytest on the connector tests: 13 passed. ruff format, ruff check and ty check are clean on the new package.
  • Real data, wind farm A converted and written with TimeFDataset.write, then read back with TimeFReader.verify(): 22 Records × 82 Signals, 34 classification and 12 localization tasks. The labels (12 anomaly / 10 normal; 6 hydraulic, 3 gearbox, 2 generator bearing, 1 transformer) match the release's event table. Conversion took 76 s on a 2-core Codespace, and the written version is 84 MB.
  • I have not run a full timenet-build build fraunhofer-iee/care-to-compare over all three farms. Wind farm C needs roughly 40 GB of free disk for extraction and cache.

ShaoSK and others added 3 commits November 17, 2026 09:42
…connector API

Main changed the connector API. A label set carries its name as an
annotation, a Hugging Face connector passes its Hub settings as class
keywords and reads a mapping from part to path, BaseConnector names the
whole download result, and Annotation takes its value by keyword.